<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>TILE!™ Support &#187; Equipment Drivers</title>
	<atom:link href="http://www.tilesupport.com/tilesupport/category/blog/equipment-drivers/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.tilesupport.com/tilesupport</link>
	<description></description>
	<lastBuildDate>Tue, 27 Sep 2011 15:45:22 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>EMCO Ortho-Axis Controller driver</title>
		<link>http://www.tilesupport.com/tilesupport/emco-ortho-axis-controller-driver/</link>
		<comments>http://www.tilesupport.com/tilesupport/emco-ortho-axis-controller-driver/#comments</comments>
		<pubDate>Tue, 05 May 2009 19:56:32 +0000</pubDate>
		<dc:creator>Joe Tannehill</dc:creator>
				<category><![CDATA[Equipment Drivers]]></category>
		<category><![CDATA[FAQs]]></category>
		<category><![CDATA[GTEM]]></category>
		<category><![CDATA[ortho]]></category>

		<guid isPermaLink="false">http://www.tilesupport.com/tilesupport/?p=75</guid>
		<description><![CDATA[&#160; It appears there maybe some issues with the ortho-axis controller for GTEM&#8217;s.&#160; The issues may be associated with the mechanical installation of the controller.&#160; To level set TILE! users for the proper setup you can reference the 5407 GTEM&#160;manual (link below) to see if you are connected correctly.&#160; If you are still having trouble [...]]]></description>
			<content:encoded><![CDATA[<p>&nbsp;</p>
<p>It appears there maybe some issues with the ortho-axis controller for GTEM&#8217;s.&nbsp; The issues may be associated with the mechanical installation of the controller.&nbsp; To level set TILE! users for the proper setup you can reference the 5407 GTEM&nbsp;manual (link below) to see if you are connected correctly.&nbsp; If you are still having trouble contact us.</p>
<p>http://www.ets-lindgren.com/manuals/5407.pdf</p>
<p>Joe Tannehill</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.tilesupport.com/tilesupport/emco-ortho-axis-controller-driver/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Agilent E4440A w/Preselector (PSA)</title>
		<link>http://www.tilesupport.com/tilesupport/agilent-e4440a-wpreselector-psa/</link>
		<comments>http://www.tilesupport.com/tilesupport/agilent-e4440a-wpreselector-psa/#comments</comments>
		<pubDate>Thu, 09 Apr 2009 21:11:33 +0000</pubDate>
		<dc:creator>Joe Tannehill</dc:creator>
				<category><![CDATA[Equipment Drivers]]></category>
		<category><![CDATA[E4440A]]></category>
		<category><![CDATA[N9039]]></category>
		<category><![CDATA[Preselector]]></category>
		<category><![CDATA[PSA]]></category>

		<guid isPermaLink="false">http://www.tilesupport.com/tilesupport/?p=12</guid>
		<description><![CDATA[&#160; I have found an issue wih the PSA when using the preselector in &#8216;filter&#8217; mode.&#160; If the PS is in filter mode and a start frequency of 30MHz or stop frequency of 1GHz is commanded (even from the front panel) the result will be a &#8216;compressed&#8217; 10Hz span at either 29.999MHz or 999.999MHz.&#160; Example: [...]]]></description>
			<content:encoded><![CDATA[<p>&nbsp;</p>
<p>I have found an issue wih the PSA when using the preselector in &#8216;filter&#8217; mode.&nbsp;</p>
<p>If the PS is in filter mode and a start frequency of 30MHz or stop frequency of 1GHz is commanded (even from the front panel) the result will be a &#8216;compressed&#8217; 10Hz span at either 29.999MHz or 999.999MHz.&nbsp;</p>
<p>Example:</p>
<p>CF: 500MHz</p>
<p>Span: 1MHz</p>
<p>Change to:</p>
<p>Start Freq:&nbsp; 30MHz</p>
<p>Result:</p>
<p>29.999MHz to 30MHz.</p>
<p>NOTE:&nbsp; This does not happen if the preselector is in BYPASS.</p>
<p>This will be evident when you are using a &#8216;scan&#8217; type of action such as Optimize.&nbsp;</p>
<p><strong>Work around:</strong></p>
<p>Place two GPIB&nbsp;actions in the flowchart before the scan action.</p>
<p>In the first one:&nbsp; PSA:&quot;sense:freq:star 30MHz&quot;</p>
<p>In the second one:&nbsp; PSA:&quot;sense:freq:stop 1GHz&quot;</p>
<p>If I put them in the same one there was not enough time to set it.</p>
<p>I have contacted Agilent about this and will post here when I see the fix.</p>
<p>&nbsp;</p>
<p>Joe Tannehill</p>
]]></content:encoded>